Del Mar Photonics featured customer
    ![]()  | 
    
    Prof. A.Gh PodoleanuHead of Applied Optics GroupProfessor of Biomedical OpticsIngram Building Rm.301  | 
  
Low-Coherence Interferometry is a powerful tool to "section" a transparent object. The technique is currently evolving quickly with applications in medicine in general and ophthalmology in particular. The OCT technology is non-invasive and provides high depth resolution, therefore the technology was applied to different types of tissue, skin, hair, burns, etc. Visualisation of cells, microorganisms, hair, brain and the interior of arteries have been reported with depth and transversal resolution of 5-15 microns. OCT has also been used to image integrated circuits, characterise fibre Bragg gratings and optical waveguides and in surface analysis. In combination with confocal microscopy, OCT can in principle offer 1 micron resolution along all three axes. The OCT field requires an interdisciplinary approach.
The AOG in Kent is at the forefront of OCT system development. The group has pioneered the en-face OCT technology, the first dual channel confocal-OCT instrument for the eye, multi-interferometer configuration to collect simultaneously images from different depths and produced 3D OCT visualisation in real time.
OCT technology
 
Early OCT in the AOG
 
| A. Gh. Podoleanu S. Taplin  D. J. Webb D. A. Jackson  | 
    Theoretical Study of Talbot-like Bands Observed Using a Laser Diode Below Threshold | J.    Pure and Applied Optics, Vol. 7, (1998), 
    pp. 517-536. http://stacks.iop.org/PAO/7/517  | 
  
| A. Gh. Podoleanu S. Taplin  D. J. Webb D. A. Jackson  | 
    Talbot-like Bands for Laser Diode Below Threshold | J. Pure and Applied Optics, vol. 6, issue 3, 
    pp. 413 - 424, (1997). http://stacks.iop.org/PAO/6/413  | 
  
| A. Gh. Podoleanu  S. Taplin D. J. Webb D. A. Jackson  | 
    Channeled Spectrum Display using a CCD Array 
    for  Student Laboratory Demonstrations  | 
    European J. Phys., 15, pp. 266-271, (1994).  http://stacks.iop.org/EJP/15/266  | 
  
| A. Gh. Podoleanu S. Taplin,  D. J. Webb, D. A. Jackson  | 
    Channelled Spectrum Liquid Refractometer | Rev. Sci. Instr., vol. 64, No.10,  pp. 3028-9, 
    (1993).  | 
  
| S. Taplin,  A. Gh. Podoleanu D. J. Webb, D. A. Jackson  | 
    Displacement Sensor Using  Channeled Spectrum 
    Dispersed on a  Linear CCD Array  | 
    Electron. Lett.  29, No.10, (1993), pp. 896-897.  | 
  
En-face 
flying spot OCT
First, we have shown that a Newton ring pattern is sampled from the target
| A. Gh.Podoleanu  G. M. Dobre D. J. Webb D. A. Jackson  | 
    Coherence Imaging by Use of a Newton Rings 
    Sampling Function,  Republished in “Selected Papers on Optical Low-Coherence Reflectometry & Tomography”, B. R. Masters and B. J. Thompson eds., SPIE Milestone Series, vol. MS165, SPIE Optical Engineering Press, Washington, 2000, USA, pp. 200-202.  | 
    Opt. Lett., Vol. 21, pp. 1789-1791, (1996).  http://www.opticsinfobase.org/abstract.cfm?id=45207  | 
  
Then we moved the centre 
of the Newton rings out from the image centre and sampled the target with a grid 
of line
| A. Gh.Podoleanu  G. M. Dobre D. A. Jackson  | 
    En-face Coherence Imaging Using Galvanometer Scanner Modulation | Opt. Letters, (1998), vol. 23, pp.  147-149. http://www.opticsinfobase.org/abstract.cfm?id=36537  | 
  
This report demonstrates for the first time, B-scan OCT images from the retina constructed from T-scans (en-face 1D OCT scans)
| A. Gh.Podoleanu  M. Seeger, G. M. Dobre D. J. Webb D. A. Jackson, F. Fitzke  | 
    Transversal and Longitudinal Images from the 
    Retina of the Living Eye Using Low Coherence Reflectometry,  Republished in “Selected Papers on Optical Low-Coherence Reflectometry & Tomography”, B. R. Masters and B. J. Thompson eds., SPIE Milestone Series, vol. MS165, SPIE Optical Engineering Press, Washington, 2000, USA, pp. 461-469.  | 
    Journal of Biomedical Optics, 3, (1), (1998),
     pp. 12-20. http://www.spie.org/web/journals/jbo/jbo_jan98.html  | 
  
The OCT/SLO
(collaboration with
Ophthalmic Technologies Inc.)
 
The research on flying spot en-face OCT has shown us how to produce OCT images with the same orientation as that in microscopy, or in scanning laser ophthalmoscopy (SLO). This allowed us to devise and assemble a dual imaging system. The system outputs pairs of OCT and confocal images. Several ophthalmoogy groups are now using the OCT/SLO in imaging the eye.
| A. Gh. Podoleanu D. A. Jackson | Combined Optical Coherence Tomograph and Scanning Laser Ophthalmoscope | Electron. Lett., Vol. 34, No. 11, (1998) pp. 1088-1090. | 
Recognisable patterns in the OCT C-scans could be associated to several diseases for easier diagnostic
Collaboration with New York Eye and Ear 
Infirmary and the
Department of Ophthalmology 
     Academic Medical Center, University of Amsterdam
M. E. 
J. Van Velthoven, F. D.Verbraak, L. A. Yannuzzi,
R. B. Rosen, A. Gh. 
Podoleanu, Marc D. De Smet, Imaging the Retina by En-Face Optical Coherence 
Tomography, RETINA, 26:129–136, 2006. RETINA-THE JOURNAL OF RETINAL AND VITREOUS 
DISEASES, Issues/Year: 6.
First OCT/ICG instrument for the eye, 
collaboration with New York Eye and Ear 
Infirmary
 
| G. M. Dobre  A. Gh. Podoleanu R. B. Rosen  | 
    Simultaneous optical coherence tomography–Indocyanine
     Green dye fluorescence imaging system for investigations of the eye’s fundus  | 
    Optics Letters, Vol. 30, No. 1 / January 1, 
    2005, 58-60.  | 
  
Ultra high resolution OCT/SLO system, 
collaboration with 
New York Eye and Ear Infirmary
 
| R. G. Cucu  A.Gh. Podoleanu J. A. Rogers J. Pedro R. B. Rosen  | 
    Combined confocal scanning ophthalmoscopy/en 
    face T-scan based ultrahigh resolution OCT of the human retina in 
    vivo  | 
    Optics Letters, Vol. 31, No. 11, June 1, 2006, 
    1684-1687. http://www.opticsinfobase.org/abstract.cfm?id=89811  | 
  
First OCT/SLO with AO correction, 
collaboration with 
National University of Ireland, Galway
 
| R. G. Cucu  A.Gh. Podoleanu J. A. Rogers J. Pedro R. B. Rosen  | 
    Combined confocal scanning ophthalmoscopy/en 
    face T-scan based ultrahigh resolution OCT of the human retina in 
    vivo  | 
    Optics Letters, Vol. 31, No. 11, June 1, 2006, 
    1684-1687. http://www.opticsinfobase.org/abstract.cfm?id=89811  | 
  
Sequential OCT/confocal
Sequential instead of simultaneous allows all signal to be used in each channel, 
OCT or confocal (SLO).
(collaboration with 
New York Eye and Ear Infirmary) 
| A.Gh.Podoleanu  G. M.Dobre R. G. Cucu R. Rosen  | 
    Sequential OCT and Confocal Imaging | Opt. Letters, 29 (4): 364-366 Feb. 15 2004 http://www.opticsinfobase.org/abstract.cfm?id=78717  | 
  
Modulators and scanning methods for OCT
Using two RF modulators, we 
demonstrated simultaneous acquisition of two C-scans at two different depths
 
| A. Gh.Podoleanu  G. M. Dobre D. J. Webb D. A. Jackson  | 
    Simultaneous En-face Imaging of Two Layers in Human Retina | Opt. Lett., Vol. 22, No. 13,  pp. 1039-1041, (1997) http://www.opticsinfobase.org/abstract.cfm?id=36206  | 
  
Using a 
Mach Zehnder integrated modulator with independent RF excitation in each arm, we 
demonstrated simultaneous acquisition of two C-scans at two different depths, 
collaboration with University of Besancon
 
| A.Gh. Podoleanu J. A. Rogers,  R. C. Cucu D. A. Jackson B Wacogne H. Porte T. Gharbi  | 
    Simultaneous Low Coherence Interferometry Imaging at Two Depths Using an Integrated Optic Modulator | Optics Communications, 191  (1-2): 21-30, May, 1, 2001.  | 
  
Novel scanning delay line 
for fast A-scan but with less loss
 
| C. C. Rosa  J. Rogers A.Gh. Podoleanu  | 
    Fast Scanning Transmissive Delay Line Optical 
    Coherence Tomography  | 
    Opt. Lett. 30, 3263-3265 (2005) http://www.opticsinfobase.org/ abstract.cfm?URI=ol-30-24-3263  | 
  
Using two coupled interferometers we devised a novel method for measuring the 
eye length
 
| A. Gh.Podoleanu,  G. M. Dobre D. J. Webb D. A. Jackson  | 
    Fiberised Set-up for Eye Length Measurement | Full length article in Optics Commun., 137, pp. 397-405, (1997) | 
Signal to noise ratio analysis
Comparative noise analysis in 
the two channels of an OCT/SLO system
 
| A. Gh.Podoleanu  D. A. Jackson  | 
    Noise Analysis of a Combined Optical Coherence 
    Tomograph and a Confocal Scanning Ophthalmoscope  Republished in “Selected Papers on Optical Low-Coherence Reflectometry & Tomography”, B. R. Masters and B. J. Thompson eds., SPIE Milestone Series, vol. MS165, SPIE Optical Engineering Press, Washington, 2000, USA, pp. 511-526.  | 
    Appl. Optics, Vol. 38, (1999), No. 10, pp. 2116 
    -   2127. http://www.opticsinfobase.org/abstract.cfm?id=44269  | 
  
This reports shows that fast OCT system have to work in excess photon noise 
regime limitation and not in shot noise regime
 
| A.Gh.Podoleanu | Unbalanced versus balanced operation in an OCT system | Appl. Opt., 2000, Vol. 39, No. 1, pp. 173-182. http://www.opticsinfobase.org/abstract.cfm?id=914  | 
  
Two novel noise bandwidth definitions are 
introduced to consider the excess photon noise in balanced OCT under wide 
bandwidth excitation
 
| C. C. Rosa,  A. Podoleanu  | 
    Limitation of the achievable signal to noise ratio in OCT due to mismatch of the balanced receiver | Applied Optics, 43 (25): 4802-4815, 2004 http://www.opticsinfobase.org/abstract.cfm?id=80957  | 
  
Corrections of distortions in OCT images
We make distinction between 
scanning and refractive type distortions in OCT. This report also predicts a 
distorted elevation of the RPE layer in the fovea in the OCT images of the 
retina, due to differences in the indeces of refraction of vitreous and retina
(collaboration with University of 
Central Florida, School of Optics / CREOL and New York Eye and Ear Infirmary)
 
| A. Podoleanu  I. Charalambous L. Plesea, A. Dogariu R. Rosen  | 
    Correction of distortions in OCT imaging of the eye | Physics in Medicine and Biology, 49,  2004, 1277-1294. http://www.iop.org/EJ/abstract/0031-9155/49/7/015/ http://stacks.iop.org/PMB/49/1277  | 
  
OCT in ophthalmology
Posterior pole
The majority of reports above 
referred to examples in imaging the retina. 
A novel method for 
topography using en-face OCT was 
presented in the following report
(collaboration with 
Institute of Ophthalmology, London)
 
| J. A. Rogers  A.Gh. Podoleanu G. M. Dobre D. A. Jackson F. W. Fitzke  | 
    Topography and volume measurements of the optic 
    nerve  using en-face optical coherence tomography  | 
    Opt. Express, Vol. 9, No. 10, Nov. 5, 2001,  pp. 476 – 545 http://www.opticsexpress.org/oearchive/source/34986.htm  | 
  
The utility of 
adjustable depth resolution required by en-face OCT method is presented in:
 
| A.Gh.Podoleanu  J. A. Rogers D. A. Jackson  | 
    OCT En-face Images from the Retina with 
    Adjustable Depth Resolution in Real Time | 
    IEEE Journal of Selected Topics in Quantum 
    Electron.,  1999, Vol.5, No.4, 1176-1184. http://ieeexplore.ieee.org/search/wrapper.jsp? arnumber=796344 or http://ieeexplore.ieee.org/iel5/2944/17287/00796344.pdf?tp= &arnumber=796344&isnumber=17287 =&arnumber=796344&isnumber=17287  | 
  
Anterior pole
 
| A. Gh. Podoleanu  J. A. Rogers G. M. Dobre, R. G. Cucu, D. A. Jackson  | 
    En-face OCT imaging of the anterior chamber | Coherence Domain Optical Methods in Biomedical Science and Clinical Applications V, SPIE Proc. Vol. 4619, V. V. Tuchin, J. A. Izatt, J. G. Fujimoto eds, Photonics West, SPIE Conf. BIOS2002, Jan. 21-23 Jan., 2002, pp. 240-243. | 
OCT in imaging skin
3D images are constructed from
en-face OCT
 
| A.Gh.Podoleanu  J. A. Rogers D. A. Jackson S. Dunne  | 
    Three dimensional OCT images from retina and skin | Opt. Express, Vol. 7,  No. 9,  p. 292-298, (2000), http://www.opticsexpress.org/abstract.cfm?URI=OPEX-7-9-292  | 
  
OCT in dentistry
(collaboration with
School of Dentistry,
University of 
Liverpool) 
| B. T. Amaechi  S.M.Higham A.Gh. Podoleanu J. A. Rogers D. A. Jackson  | 
    Use of optical coherence tomography for assessment of dental carries: quantitative procedure | Journal of Oral Rehabilitation, 2001, 28, pp. 1092-1093 | 
| B. T. Amaechi,  A. Gh. Podoleanu S.M. Higham D. Jackson  | 
    Correlation of Quantitative Light-induced 
    Fluorescence and Optical Coherence Tomography  Applied for Detection and Quantification of Early Dental Caries  | 
    Journal Biomedical Optics,  8(4); 642-647; 2003  | 
  
OCT in imaging larynx and cochlea
(Collaboration with Otolaryngology-Head & Neck Surgery Department, Guy's 
Hospital, London)
 
OCT in imaging breast tissue
(Collaboration 
with the Department of Histopathology,
Imperial College School of Medicine,
Hammersmith Hospital, London)
 
| P. J. Tadrous  A. Gh. Podoleanu S. Shousha et al.  | 
    3D tissue imaging - A practical method using automated image registration and its application to the development of in vivo histological imaging techniques | J. Pathology  195: 1A-1A Suppl. S Sep. 2001  | 
  
| P. J. Tadrous  A. Gh. Podoleanu G. M. Dobre G.W.H. Stamp  | 
    Application of VRML for 3-dimensional, interactive, real-time comparison of OCT structures with standard histology | Coherence Domain Optical Methods and Optical 
    Coherence Tomography in Biomedicine VII,  Valery V. Tuchin, Joseph A. Izatt, James G. Fujimoto, Editors, Proceedings of SPIE Vol. 4956 (2003) © 2003 SPIE · 1605-7422/03/ Photonics West, BIOS2003, Jan. 27-29 Jan., p. 42-47.  | 
  
Profilometry of craters using coherence 
radar
 
| L. Kay  A. Gh.Podoleanu M. Seeger C. J. Solomon  | 
    A New Approach to the Measurement and Analysis of Impact Craters | Int. J. Impact Engn., Vol. 19, No. 8, 739-753, (1997). | 
Imaging paintings
En-face OCT allows visualisation of 
under-drawings
(Collaboration 
with the Nottingham Trent University, British Museum London and National 
Gallery, London)
 
| H. Liang  M. G. Cid R. Cucu G.M. Dobre J. Pedro D. Saunders A. Gh. Podoleanu  | 
    Application of Optical Coherence  Tomography to Examination of Easel Paintings  | 
    Optics Express, Vol. 13, No. 16 August 08, 2005, p. 6133 - 6144 http://www.opticsexpress.org/abstract.cfm?URI=OPEX-13-16-6133 | 
Gallery of some OCT images, others can be viewed by linking to the web pages 
indicated in the 
A. Podoleanu's 
publication list
 
Terminology (transversal or en-face versus longitudinal)
 
Surface analysis and volume imaging using Coherence Radar
Achievements: