Del Mar Photonics - Hatteras brochure - Request a quote - Custom Femtosecond Transient Absorption Data Acquisition Systems
    ![]()  | 
    Femtosecond Transient Absorption Measurements system
    Hatteras.  Future nanostructures and biological nanosystems will take advantage not only of the small dimensions of the objects but of the specific way of interaction between nano-objects. The interactions of building blocks within these nanosystems will be studied and optimized on the femtosecond time scale - says Sergey Egorov, President and CEO of Del Mar Photonics, Inc. Thus we put a lot of our efforts and resources into the development of new Ultrafast Dynamics Tools such as our Femtosecond Transient Absorption Measurements system Hatteras. Whether you want to create a new photovoltaic system that will efficiently convert photon energy in charge separation, or build a molecular complex that will dump photon energy into local heat to kill cancer cells, or create a new fluorescent probe for FRET microscopy, understanding of internal dynamics on femtosecond time scale is utterly important and requires advanced measurement techniques.  | 
  
Relaxation Dynamics of Ruthenium Complexes in Solution, PMMA and TiO2 
Films: The Roles of Self-Quenching and Interfacial Electron Transfer
Chih-Wei Chang, Chung Kuang Chou, I-Jy Chang, Yuan-Pern Lee, and Eric 
Wei-Guang Diau*,
Department of Applied Chemistry and Institute of Molecular Science, National 
Chiao Tung UniVersity,
No. 1001, Ta Hsueh Road, Hsinchu 30010, Taiwan, and Department of Chemistry, 
National Taiwan
Normal UniVersity, No. 88, Sec. 4, Ting-Chow Road, Taipei 11677, Taiwan
The relaxation dynamics of two transition-metal complexes, [Ru(bpy)3]2+ and 
[Ru(bpy)3(mcbpy)]2+, in ethanol solution and in poly(methyl methacrylate) (PMMA) 
and TiO2 films have been investigated with time-resolved emission and 
femtosecond transient absorption spectroscopy. The emission lifetime of a 
degassed [Ru(bpy)3]2+ solution in ethanol was determined to be 700 ns; to 
describe the self-quenching kinetics due to aggregation, three decay 
coefficients, 5.3, 70, and 220 ns, were obtained for the [Ru(bpy)3]2+/PMMA film. 
The electron
transfer through space in a [Ru(bpy)3]2+/TiO2 film competed with intrinsic 
intersystem crossing ( 100 fs) and vibrational relaxation ( 6 ps) in solid 
films. For the [Ru(bpy)2(mcbpy)]2+/TiO2 film, although the relaxation for 
electron transfer through bonds was more rapid than electron transfer through 
space, both processes occur on similar time scales. Through femtosecond 
transient absorption measurements, we provide important dynamical evidence for 
the interfacial electron transfer in both forward and backward directions. We 
conclude that in dye-sensitized solar-cell applications processes for 
interfacial electron transfer are significant not only through bonds but also 
through space.
Femtosecond Transient Absorption Measurements. Femtosecond transient 
absorption spectra were recorded with a pump-probe spectrometer (sold in 
Americas under brand name Hatteras - Del Mar Photonics) in combination with an 
ultrafast amplified laser system. The amplified laser pulses were obtained from 
a regenerative amplifier (Legend-USP-1KHE, Coherent) seeded with a mode-locked 
Ti:sapphire laser system (Mira-Seed/ Verdi V5, Coherent) and pumped with a 1-kHz 
Nd:YLF laser (Evolution 30, Coherent). The laser pulses are centered at 800 nm 
with an average energy 2.5 mJ pulse-1. The FWHM of the amplified pulses ( 60 fs) 
was determined by a single-shot autocorrelator (Coherent). The amplified pulse 
was equally split to pump two optical parametric amplifiers (OPerA-F, Coherent) 
in combination with harmonic generations (SHG, THG, and FHG), sum-frequency 
generation (SFG), and difference-frequency generation modules, which provide 
tunable femtosecond pulses in the wavelength range 240 nm-10
΅m.
Figure 1 shows the optical layout of the femtosecond pump-probe TA spectrometer. 
Basically, the dye molecules in an electronic excited-state can be prepared by 
an excitation pulse (Pump); the resulting transient species and their relaxation 
dynamics can be monitored by a probe pulse (Probe). The polarization of the 
excitation pulse was controlled with a Berek compensator (B1), and the pump beam 
was focused onto the rotating sample cell containing the solution or thin-film 
samples. For single-wavelength kinetic measurements, the probe pulse was 
generated with the OPA/wavelength converter; for transient absorption spectral 
measurements, the white-light (WL) continuum was produced on focusing the 
residual amplified pulse (800 nm) on a continuous water-flow cell (WL cell). To 
record transient absorption spectra with and without the excitation pulses, we 
used a chopper to modulate the excitation pulse.
E-mail for complete article

Figure 1. Optical layout of the femtosecond transient absorption 
spectrometer. M1-M5, gold or aluminum mirrors; BS1 and BS2, beam splitters;
Wedge, wedge prism; B1, Berek compensator; WP, half-wave plate; Pl, polarizer; 
L1 and L2, lens; AC1-AC4, achromatic lens; FC1 and FC2,
optical fiber couplers; PD, photodiode; R, retro-reflector. For single 
wavelength measurements, the white-light (WL) cell was removed, and both
FC1 and FC2 were replaced with two photodiodes.
More Hatteras customers:
1. National Taiwan University, Taipei, Taiwan (Prof. 
Pi-Tai Chou)
2. National Tsing Hua University, Hsinchu, Taiwan (Prof. 
I-Chia Chen)
3. Toyota CRDL Inc., Aishi, Japan
4. Tokyo Metropolitan University, Tokyo, Japan
5. Osaka University, Osaka, Japan
6. International Laser Center, Bratislava, Slovak Republic
7. Institute of Physical Biology, Nove Hrady, Czech Republic
8. Institute of Spectroscopy, Troitsk, Russian Federation
9. Nanoparticle Manufacturing 
Laboratory, University of Leeds, Leeds, UK - Yasir Khan  Technician
y.khan@leeds.ac.uk  
10. University of Joensuu, Joensuu, Finland
11. Universidad de Castilla-La Mancha, Toledo, Spain
E-mail us to receive complete contact details of our Hatteras customers
Hatteras Specifications:
Hatteras femtosecond transient absorption 
pump-probe system: 
Input requirements: > 0.5 mJ at 800 nm, < 100 fs, 1 kHz
1. All optics and mechanics for pump  probe measurements, assembled on a 
breadboard with cover box: femtosecond white light (continuum) generator for 
probe and reference pulse formation at 400  1600 nm; 2.0 -ns optical delay 
line; transmission and reflection configurations; optics for fluorescence 
anisotropy measurements; rotating sample cell assembly; holder for solid samples 
and thin films; set of selected color and neutral density filters.
2. Multi channel detector head, with two 1024-pixels extra-deep well NMOS linear 
image sensors, 200 -1000 nm spectral response (10% of peak), > 5800 dynamic 
range, up to 1 kHz readout rep. rate
3. Hatteras 2022i imaging spectrometer, adapted to the detector head and 
connected to a computer via serial port:
4. Photodiode for the system synchronization
5. Photodiode for pump power measurements
6. Synchronized chopper 
7. Hatteras 3.0 data acquisition, chirp correction, 3D and kinetic analysis 
software
Infrared multichannel detector head (option), with two 256-pixels InGaAs linear 
image sensors, 100 -1700 nm spectral response (10% of peak), > 5800 dynamic 
range, up to 1 kHz readout rep. rate
Standard Hatteras quote based on US 
Domestic list price. Add 10% for International quotes.
E-mail us for a custom quote
Hatteras advantages:
Main advantages of Hatteras pump-probe (transient absorption) spectrometer:
1. We use pump-probe configuration, where two signals (probe and reference) are 
measured by two linear image sensors. This configuration is very important for 
precision optical density changes (ΔOD) measurements, because one can get 
results independent on probe beam fluctuations. Calculation of probe to 
reference ratio is the key principle of the pump - probe method. 
2. Two linear image sensors of Hatteras are placed in the focal plane of high 
quality imaging spectrometer. Standard grating covers 206 nm spectral range 
(other gratings are available optionally), and central wavelength is computer 
controlled.
3. Hatteras2022C imaging spectrometer has two outputs. Multichannel detector 
head is mounted on the first one, and the second one is for optional single 
channel detector head, containing two (probe and reference) photodiodes. This 
single channel option is important for high quality transient absorption 
kinetics measurements at given wavelength. Because of larger photo detector area 
and larger detector dynamic range, single channel system usually gives better 
ΔOD sensitivity than multichannel one (both systems use probe and reference 
beams).
4. Del Mar Photonics offers:
 Si multi channel head (200 nm  1000 nm), 
 InGaAs multi channel head (900 nm  1700 nm),
 Si single channel detector head (320 nm  1060 nm, 190 nm  1100 nm on 
request)
 InGaAs single channel head (900 nm  1700 nm, 900 - 2000 nm on request)
 CdHgTe (1΅m - 17΅m) 
single channel head
Hatteras is an open system. If you order visible multi channel head as a basic 
one, in future you can order other heads and connect to your control unit. One 
multi channel and two single channel heads can be connected to the control unit 
simultaneously. 
5. Hatteras-T kit of optical and mechanical components is flexible to satisfy 
users requirements. For example, a configuration with two single channel heads 
is used for one  scan anisotropy kinetic measurements (kinetics are recorded 
simultaneously for parallel and perpendicular polarization).
6. Hatteras configurations give possibilities to direct probe and reference 
beams to the entrance slit of the monochromator with help of fiber leads or 
directly. First method is simpler. Second method requires more precise 
adjustments, but gives better S/N, especially in UV region.
7. Specially designed rotation cell is used in the Hatteras. It gives a 
possibility of pseudo single-shot experiment, when every pulse at 1 kHz hits a 
fresh sample.
8. Linear image sensors with 1024 pixels (sensitive at 200 nm  1000 nm) are 
used in the Hatteras.
9. Extra-deep well photodiode linear image sensors are used in the Hatteras. 
These sensors were specially designed for photometric applications like 
transient absorption pump-probe experiments where very small signal changes 
should be detected.
10. 2.0 ns delay line with 0.78 fs min step is used in the Hatteras. 1.6 ns 
delay line with 3.5 fs min step is used by Newport.
11. Pump pulse energy is measured for every pulse (special photodiode is used 
for this purpose). Pump pulse margins or normalization can be applied for 
further S/N improving. 
12. Hatteras2017 frequency conversion option (optical parametric amplifier with 
frequency mixing and second harmonic) was specially designed to make pump beam 
easy tunable in 480 nm  800 nm spectral range. Although one can use other 
optical parametric amplifiers, Hatteras 2017 gives cheaper solution and better 
matching with Hatteras.
13. Alternatively, TOPAS is recommended as computer controlled OPA operated with 
Hatteras software. 
14. Hatteras has been designed in 1999  2000 for precision measurements of 
small photo induced optical density changes (ΔOD) in wide spectral range. Using 
our own many years experience in pump-probe experiments, as well as experience 
of leading laboratories, all components were specially designed, selected, and 
tested to make state-of-the-art system with best specifications. Hatteras is 
first femtosecond transient absorption spectrometer on the market.
 
    ![]()  | 
    Femtosecond Transient Absorption Measurements system
    Hatteras.  Future nanostructures and biological nanosystems will take advantage not only of the small dimensions of the objects but of the specific way of interaction between nano-objects. The interactions of building blocks within these nanosystems will be studied and optimized on the femtosecond time scale - says Sergey Egorov, President and CEO of Del Mar Photonics, Inc. Thus we put a lot of our efforts and resources into the development of new Ultrafast Dynamics Tools such as our Femtosecond Transient Absorption Measurements system Hatteras. Whether you want to create a new photovoltaic system that will efficiently convert photon energy in charge separation, or build a molecular complex that will dump photon energy into local heat to kill cancer cells, or create a new fluorescent probe for FRET microscopy, understanding of internal dynamics on femtosecond time scale is utterly important and requires advanced measurement techniques.  |